24
In case of returns ensure that the unit is free from soiling, especially of
dangerous and toxic substances�
For transport only use appropriate packaging to avoid damage of the unit�
11 Notes on the regulation (EC) 1935/2004
The following components of the product are designed for permanent
contact with food according to the regulation (EC) 1935/2004:
- Sensor tip made of PEEK
- Sealing ring made of PEEK (→ 5.2.2)
- Sealing ring made of FKM (LMT104 / LMT105)
12 Factory setting
LMTx0x LMTx1x LMTx2x User settings
SP1 62 % 8 % 35 %
rP1 54 % 5 % 29 %
ou1 Hno Hno Hno
SP2 62 % 8 % 35 %
rP2 54 % 5 % 29 %
ou2 Hnc Hnc Hnc
FOU1 OFF OFF OFF
FOU2 OFF OFF OFF
dS1*
)
0�0 0�0 0�0
dS2*
)
0�0 0�0 0�0
dr1 0�0 0�0 0�0
dr2 0�0 0�0 0�0
P-n PnP PnP PnP
dFo 0�0 0�0 0�0
Percentage values refer to the process value (→ 8 Parameter setting)
*
)
Parameter is not available for LMT100, LMT110 and LMT121