32 - IE
INSTALLERUSER
MAINTENANCE TECHNICIAN
N.B.: the power data in the table has been
obtained with intake-exhaust pipe measuring 0.5
m in length. Gas ow rates refer to heating values
below a temperature of 15°C and at a pressure of
3.21 VARIABLE HEAT POWER.
3.20 YEARLY CONTROL AND
MAINTENANCE OF THE
APPLIANCE.
e following checks and maintenance should
be performed at least once a year.
- Clean the ue side of the heat exchanger.
- Clean the main burner.
- If deposits are detected in the combustion
chamber one must remove them and clean
the exchanger coils using nylon or sorghum
brushes; it is forbidden to use brushes made
of metal or other materials that may damage
the combustion chamber itself.
- Check the integrity of the insulating panels
inside the combustion chamber and if damaged
replace them.
- Visually check for water leaks or oxidation
from/on connections and traces of condensate
residues inside the sealed chamber.
- Check contents of the condensate drain trap.
- Via the condensate drain cap check that there
are no residues of material that clog condensate
passage; also check that the entire condensate
drainage circuit is free and ecient.
In the event of obstructions (dirt, sediment,
etc.) with consequent leakage of condensate
in the combustion chamber, one must replace
the insulating panels.
- Check that the burner seal gaskets and the lid
are intact and perfectly ecient, otherwise
replace them. In any case the gaskets must be
replaced at least every two years, regardless of
their state of wear.
- Check that the burner is intact, that it has no
deformations or cuts and that it is properly
xed to the combustion chamber lid; otherwise
it must be replaced.
- Visually check that the water safety drain valve
is not blocked.
- Check that the system static pressure (with
system cold and aer relling the system by
means of the ller cock) is not below 0.5 bar.
- Check visually that the safety and control
devices have not been tampered with and/or
shorted, in particular:
- temperature safety thermostat.
- Check the condition and integrity of the
electrical system and in particular:
- electrical power cables must be inside the
fairleads;
- there must be no traces of blackening or
burning.
- Check correct lighting and operation.
- Check correct calibration of the burner in
central heating phase.
- Check correct operation of control and
adjustment devices and in particular:
- intervention of main electrical switch on
boiler;
- system regulation probes intervention;
- Check sealing eciency of gas circuit and the
internal system.
- Check the intervention of the device against no
gas ionisation ame control. Intervention time
must be less than 10 seconds.
N.B.: on occasion of periodical maintenance of
the appliance it is appropriate also to check and
perform maintenance on the heating system, in
compliance with that indicated by the regulations
in force.
1013 mbar. Burner pressure values refer to use
of gas at 15°C.
METHANE (G20) BUTANE (G30) PROPANE (G31)
HEAT OUT-
PUT
HEAT OUT-
PUT
BURNER GAS
FLOW RATE
REVS
FAN
BURNER GAS
FLOW RATE
REVS
FAN
BURNER GAS
FLOW RATE
REVS
FAN
(kW) (kcal/h) (m
3
/h) (n°) (kg/h) (n°) (kg/h) (n°)
50.0 43000 5.37 5180 4.01 4600 3.94 5200
48.0 41280 5.16 5000 3.85 4430 3.79 5000
46.0 39560 4.95 4810 3.70 4260 3.64 4790
44.0 37840 4.74 4620 3.54 4090 3.48 4590
42.0 36120 4.53 4430 3.38 3910 3.33 4380
41.2 35398 4.45 4350 3.32 3840 3.26 4300
38.0 32680 4.11 4050 3.07 3570 3.02 3980
36.0 30960 3.90 3860 2.91 3390 2.86 3780
34.0 29240 3.69 3670 2.75 3220 2.71 3580
32.0 27520 3.48 3470 2.59 3050 2.55 3380
30.0 25800 3.26 3280 2.44 2880 2.40 3180
28.0 24080 3.05 3080 2.28 2700 2.24 2980
26.0 22360 2.84 2890 2.12 2530 2.08 2790
24.0 20640 2.62 2690 1.96 2360 1.92 2590
22.0 18920 2.41 2490 1.80 2190 1.77 2400
20.0 17200 2.19 2290 1.63 2010 1.61 2200
18.0 15480 1.97 2090 1.47 1840 1.45 2010
16.0 13760 1.76 1890 1.31 1670 1.29 1820
14.0 12040 1.54 1690 1.15 1500 1.13 1630
12.0 10320 1.32 1490 0.99 1330 0.97 1440
10.0 8600 1.10 1280 0.82 1150 0.81 1250