9
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Installation standards
is boiler can be installed outdoors in a partially pro-
tected area.
A partially protected area is one in which the boiler is not
exposed to the direct action of the weather (rain, snow,
ha il, etc.).
is type of installation is possible when permitted by
the laws in force in the appliance's country of destina-
tion.
Installation of gas appliances, ue ex-
haust pipes and combustion air intake
pipes is forbidden in places with a re
risk (for example: garages, closed park-
ing stalls), and in potentially dangerous
places.
Do not install on the vertical projection
of hobs.
Do not install in places/rooms that con-
stitute public areas of apartment build-
ings, internal stairways or other escape
routes (e.g. oor landings, entrance
halls, etc.).
Installation is also forbidden in places/
rooms that constitute public areas of
apartment buildings such as cellars, en-
trance halls, attics, los, etc., unless oth-
erwise provided for by local regulations
in force.
ese boilers, unless properly isolated,
are not suitable for installation on walls
made of combustible material.
Installing the wall recessed frame kit must guarantee
the boiler stable, ecient support.
e recessed frame kit ensures appropriate support only if in-
stalled correctly (according to the rules of good practice), follow-
ing the instructions on its instructions leaet.
e recessed frame for the boiler is not a supporting structure and
must not replace the wall removed. It is necessary to position the
boiler inside the wall.
For safety reasons against any leaks it is necessary to plaster the
boiler housing in the brick wall.
e installation of the boiler on the wall
must guarantee a stable and eective
support to the generator itself.
e plugs (standard supply) are only to be used to x the boiler to
the wall; they only ensure adequate support if inserted correctly
(according to technical standards) in walls made of solid or
semi-hollow brick or block. In the case of walls made from hollow
brick or block, partitions with limited static properties, or in any
case walls other than those indicated, a static test must be carried
out to ensure adequate support.
ese boilers are used to heat water to below boiling tem-
perature in atmospheric pressure.
ey must be connected to a central heating system and
domestic hot water circuit suited to their performance
and capacity.
Risk of damage due to corrosion caused by unsuitable
combustion air and environment.
Spray, solvents, chlorine-based detergents, paints, glue,
ammonium compounds, powders and similar cause
product and ue duct corrosion.
Check that combustion air power supply is free from
chlorine, sulphur, powders, etc.
Make sure that no chemical substances are stored in the
place of installation.