16
INSTALLER
USER
MAINTENANCE TECHNICIAN
1.14 TABLES OF EQUIVALENT LENGTH FACTORS.
TYPE OF DUCT
Equivalent length in m
of concentric pipe Ø
80/125
Concentric pipe Ø 80/125 m 1
1.0 m
Concentric bend 90° 80/125 Ø
1.9 m
Concentric bend 45° 80/125 Ø
1.4 m
Terminal complete with concentric
horizontal intake-exhaust 80/125 Ø
5.5 m
Concentric horizontal intake-exhaust
terminal 80/125 Ø
4.7 m
Terminal complete with concentric vertical
intake-exhaust 80/125 Ø
3.4 m
Concentric vertical intake-exhaust
terminal 80/125 Ø
2.7 m
Pipe 80 Ø, 1 m
Exhaust
1.0 m
Complete exhaust terminal 80 Ø, 1 m
Exhaust
2.6 m
Exhaust terminal 80 Ø
Exhaust
1.6 m
Bend 90° 80 Ø
Exhaust
2.1 m
45° 80 Ø Bend
Exhaust
1.3 m
Terminal complete with vertical
exhaust 80 Ø
Exhaust
m 3
Coupling extension pipes and concentric elbows. To install
push-tting extensions with other elements of the ue, proceed
as follows: Install the concentric pipe or elbow with the male side
(smooth) on the female section (with lip seal) to the end stop
on the previously installed element in order to ensure sealing
eciency of the coupling.
N.B.: if the exhaust terminal and/or concentric extension pipe
needs shortening, consider that the internal duct must always
protrude by 5 mm with respect to the external duct.
N.B.: for safety purposes, do not obstruct the boiler intake-ex-
haust terminal, even temporarily.
e various parts of the ue system must be checked
to ensure that they have been laid in such a way as
to prevent the coupled parts from detaching, in par-
ticular, the ue exhaust duct in the Ø80 separator kit
conguration. Should the aforesaid condition not be
adequately guaranteed, it will be necessary to use the
special clamp ring nut clip kit.
N.B.: when installing horizontal pipes, a minimum inclination
of 3% must be maintained and a section clamp with pin must
be installed every 3 metres.
Maximum extension. Each individual component has a resist-
ance corresponding to a certain length in metres of pipe with the
same diameter (par. 1.14). With installations that involve using
various types of parts, deduct the length of the added part from
the maximum admissible length of the kit.
Example: if you need to add a 90° bend to a concentric system 125
Ø you will need to deduct 1.9 m from the maximum admissible
length.