55
- * Eciencies refer to the net caloric value.
- Flue temperature values refer to an air inlet temperature of 15°C
and ow temperature of 50°C.
- e maximum sound level emitted during boiler operation is <
55dBA. e sound level value is referred to semianechoic cham-
ber tests with boiler operating at max. heat output, with extension
of ue gas exhaust system according to product standards.
- ** For type C63 it is forbidden to install the appliance as it came
out of the factory, in congurations that require shared ues in
positive pressure.
4.3 TECHNICAL DATA TABLE.
Victrix PRO 80 ErP Victrix PRO 100 ErP Victrix PRO 120 ErP
Nominal heat input kW (kcal/h) 75.3 (64722) 92.3 (79385) 114.1 (98109)
Minimum heat input kW (kcal/h) 8.6 (7439) 9.8 (8401) 11.4 (9813)
Nominal heat output (useful) kW (kcal/h) 73.0 (62780) 90.0 (77400) 111.0 (95460)
Minimum heat output (useful) kW (kcal/h) 8.2 (7052) 9.4 (8084) 11.0 (9460)
Eective thermal eciency 80/60 Nom./Min. % 97.0 / 94.8 97.5 / 96.2 97.3 / 96.4
Eective thermal eciency 50/30 Nom./Min. % 106.6 / 106.9 107.0 / 107.4 106.7 / 107.2
Eective thermal eciency 40/30 Nom./Min. % 107.3 / 107.2 107.4 / 107.6 107.2 / 107.5
Heat loss at casing with burner On/O (80-60°C) % 0.34 / 0.80 0.41 / 0.60 0.28 / 0.70
Heat loss at ue with burner On/O (80-60°C) % 0.01 / 2.20 0.01 / 1.90 0.01 / 2.0
Central heating circuit max. operating pressure bar 4.4 (0.44) 4.4 (0.44) 4.4 (0.44)
Central heating circuit max. operating temperature °C 90 90 90
Adjustable central heating temperature °C 20 - 85 20 - 85 20 - 85
Head available with 1000 l/h ow rate kPa (m H
2
O) 81.40 (8.30) 116.5 (11.88) 116.5 (11.88)
Weight of full boiler kg 83.5 106.0 114.2
Weight of empty boiler kg 79.5 95.9 102.5
Boiler water content l 4.0 10.1 11.7
Electrical connection V/Hz 230/50 230/50 230/50
Nominal absorption A 1.5 2.3 2.5
Installed electric output W 195 345 385
Pump consumption W 82 183 186
EEI - ≤ 0.23 - Part. 3 ≤ 0.23 - Part. 3 ≤ 0.23 - Part. 3
Fan power consumption W 100 154 184
Equipment electrical system protection - IPX5D IPX5D IPX5D
Max. operating room temperature °C +50 +50 +50
Min. operating room temperature °C -5 -5 -5
Min. operating room temperature with anti-freeze kit
(Optional)
°C -15 -15 -15
Flue gas max. temperature °C 75 75 75
Max. ue overheating temperature °C 120 120 120
NO
X
class - 6 6 6
Weighted NO
X
mg/kWh 25.0 20.0 33.0
Weighted CO mg/kWh 16.0 12.0 18.0
Type of appliance
C13-C13x-C33-
C33x-C43-C43x-
C53-C63-C83-C93-
C93x-C(10)3-C(12)3-
C(15)3-C(10)3X-
C(15)3X B23p-B33-
B53p
C13 / C33 / C63 / B23p / B33 / B53p
Category II2H3 P