55
- * Eciencies refer to the net caloric value.
- Flue temperature values refer to an air inlet temperature of 15°C
and ow temperature of 50°C.
- e maximum sound level emitted during boiler operation is <
55dBA. e sound level value is referred to semianechoic cham-
ber tests with boiler operating at max. heat output, with extension
of ue gas exhaust system according to product standards.
- ** For type C63 it is forbidden to install the appliance as it came
out of the factory, in congurations that require shared ues in
positive pressure.
4.3 TECHNICAL DATA TABLE.
Victrix PRO 80 ErP Victrix PRO 100 ErP Victrix PRO 120 ErP
Nominal heat input kW (kcal/h) 75.3 (64722) 92.3 (79385) 114.1 (98109)
Minimum heat input kW (kcal/h) 8.6 (7439) 9.8 (8401) 11.4 (9813)
Nominal heat output (useful) kW (kcal/h) 73.0 (62780) 90.0 (77400) 111.0 (95460)
Minimum heat output (useful) kW (kcal/h) 8.2 (7052) 9.4 (8084) 11.0 (9460)
Eective thermal eciency 80/60 Nom./Min. % 97.0 / 94.8 97.5 / 96.2 97.3 / 96.4
Eective thermal eciency 50/30 Nom./Min. % 106.6 / 106.9 107.0 / 107.4 106.7 / 107.2
Eective thermal eciency 40/30 Nom./Min. % 107.3 / 107.2 107.4 / 107.6 107.2 / 107.5
Heat loss at casing with burner On/O (80-60°C) % 0.34 / 0.80 0.41 / 0.60 0.28 / 0.70
Heat loss at ue with burner On/O (80-60°C) % 0.01 / 2.20 0.01 / 1.90 0.01 / 2.0
Central heating circuit max. operating pressure bar 4.4 (0.44) 4.4 (0.44) 4.4 (0.44)
Central heating circuit max. operating temperature °C 90 90 90
Adjustable central heating temperature °C 20 - 85 20 - 85 20 - 85
Head available with 1000 l/h ow rate kPa (m H
2
O) 81.40 (8.30) 116.5 (11.88) 116.5 (11.88)
Weight of full boiler kg 83.5 106.0 114.2
Weight of empty boiler kg 79.5 95.9 102.5
Boiler water content l 4.0 10.1 11.7
Electrical connection V/Hz 230/50 230/50 230/50
Nominal absorption A 1.5 2.3 2.5
Installed electric output W 195 345 385
Pump consumption W 82 183 186
EEI - ≤ 0.23 - Part. 3 ≤ 0.23 - Part. 3 ≤ 0.23 - Part. 3
Fan power consumption W 100 154 184
Equipment electrical system protection - IPX5D IPX5D IPX5D
Max. operating room temperature °C +50 +50 +50
Min. operating room temperature °C -5 -5 -5
Min. operating room temperature with anti-freeze kit
(Optional)
°C -15 -15 -15
Flue gas max. temperature °C 75 75 75
Max. ue overheating temperature °C 120 120 120
NO
X
class - 6 6 6
Weighted NO
X
mg/kWh 25.0 20.0 33.0
Weighted CO mg/kWh 16.0 12.0 18.0
Type of appliance
C13-C13x-C33-
C33x-C43-C43x-
C53-C63-C83-C93-
C93x-C(10)3-C(12)3-
C(15)3-C(10)3X-
C(15)3X B23p-B33-
B53p
C13 / C33 / C63 / B23p / B33 / B53p
Category II2H3 P