INSTALLERUSER
MAINTENANCE TECHNICIAN
3.26 CASING REMOVAL.
To facilitate boiler maintenance the casing can be completely
removed as follows:
- take the two screws out (3) from the bottom of the front (2);
- take the front down (2) by gripping its bottom handle, then
pulling it towards yourself to detach it from the central hooks,
and then slide it downwards;
- take the two clamping screws out (4) from the control panel,
with their rings (5);
- press the two side hooks (7) and tilt the control panel (6);
- remove the lower grid (8) by loosening the 4 screws (9);
- at this point, if necessary, you can take down the protective cover
(10) and side panels (12);
- take the cover down (10) by removing the relative screws (11);
- take down the two side panels (12) by removing the front screws
(13) and unhooking the panels (ref. A g. 53).