EasyManua.ls Logo

Immergas Victrix Pro 80 2ErP - 4.2 Combustion parameters.

Immergas Victrix Pro 80 2ErP
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
Combustion parameters: measuring conditions of useful ecien-
cy (ow temperature/return temperature= 80 / 60 °C), ambient
temperature reference = 15°C.
4.2 COMBUSTION PARAMETERS.
Victrix PRO 80 ErP
G20 G31
Gas nozzle diameter mm 12.70 8.50
Supply pressure mbar (mm H
2
O) 20 (204) 37 (377)
Flue ow rate at nominal heat output kg/h (g/s) 114 (31.67) 120 (33.33)
Flue ow rate at min heat output kg/h (g/s) 14 (3.89) 15 (4.17)
CO
2
at Q. Nom./Min. %
9.95 / 8.95
(+ 0.2 / - 0.3 %)
10.60 / 9.75
(+ 0.2 / - 0.3 %)
CO with 0% O
2
at Nom./Min. Q. Nom./Min. ppm 233 / 4 175 / 4
NO
X
at 0% of O
2
at Q. Nom./Min. mg/kWh 34 / 1 65 / 6
Flue temperature at nominal output °C 62 61
Flue temperature at minimum output °C 43 45
Victrix PRO 100 ErP
G20 G31
Gas nozzle diameter mm 11.30 8.40
Supply pressure mbar (mm H
2
O) 20 (204) 37 (377)
Flue ow rate at nominal heat output kg/h (g/s) 146 (40.56) 148 (41.11)
Flue ow rate at min heat output kg/h (g/s) 16 (4.44) 16 (4.44)
CO
2
at Q. Nom./Min. %
9.40 / 9.00
(+ 0.2 / - 0.3 %)
10.60 / 10.10
(+ 0.2 / - 0.3 %)
CO with 0% O
2
at Nom./Min. Q. Nom./Min. ppm 210 / 5 230/ 1
NO
X
at 0% of O
2
at Q. Nom./Min. mg/kWh 62 / 8 67 / 10
Flue temperature at nominal output °C 53 54
Flue temperature at minimum output °C 45 45
Victrix PRO 120 ErP
G20 G31
Gas nozzle diameter mm 16,50 9,70
Supply pressure mbar (mm H
2
O) 20 (204) 37 (377)
Flue ow rate at nominal heat output kg/h (g/s) 174 (48.33) 183 (50.83)
Flue ow rate at min heat output kg/h (g/s) 19 (5.28) 19 (5.28)
CO
2
at Q. Nom./Min. %
9.80 / 9.00
(+ 0.2 / - 0.3 %)
10.60 / 10.00
(+ 0.2 / - 0.3 %)
CO with 0% O
2
at Nom./Min. Q. Nom./Min. ppm 257 / 1 220 / 1
NO
X
at 0% of O
2
at Q. Nom./Min. mg/kWh 95 / 9 77 / 13
Flue temperature at nominal output °C 56 56
Flue temperature at minimum output °C 46 46

Table of Contents