1.16 CONCENTRIC VERTICAL KIT INSTALLATION.
• Type C conguration, sealed chamber and fan assisted.
Concentric vertical intake and exhaust kit. is vertical terminal
is connected directly to the outside of the building for air intake
and ue gas exhaust.
e vertical kit with aluminium tile enables installa-
tion on terraces and roofs with a maximum slope of
45% (approx 25°) and the height between the terminal
cap and half-shell (374 mm for Ø 60/100 and 260 mm
for Ø 80/125) must always be observed.
Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 13): install the 80/125 Ø adapter (1) on the
central hole of the boiler fully home. Slide the gasket (2) along
the adapter (1) up to the relevant groove, Fix it to the lid using
the previously-disassembled sheet steel plate (3).
Installation of the fake aluminium tile: replace the tiles with the
aluminium sheet (5), shaping it to ensure that rainwater runs o.
Position the xed half-shell (6) on the aluminium tile and insert
the intake-exhaust pipe (7). Fit the 80/125 Ø concentric terminal
pipe with the male end (6) (smooth) to the female end of the
adapter (1) (with lip gasket) up to the stop; making sure that the
wall sealing plate (4) has been tted, this will ensure sealing and
joining of the elements making up the kit.
• Maximum length (MAX L) (Fig. 14). e kit with this cong-
uration can be extended up to a max. measurement of 15.0 m
with Victrix Pro 80 2ErP, 11.0 m with Victrix Pro 100 2ErP and
6.0 m with Victrix Pro 120 2ErP, including the terminal
e kit includes:
N° 1 - Adaptor Ø 80/125 (1)
N° 1 - Gasket (2)
N° 1 - Ring (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Int./exhaust concentric
terminal Ø 80/125 (7)
N° 1 - Mobile half-shell (8)