7
INSTALLER
USER
MAINTENANCE TECHNICIAN
ATTENTION:
installation of the Victrix Pro boiler
when powered by LPG must comply
with the rules regarding gases with a greater
density than air (remember, as an example,
that it is prohibited to install plants powered
with the above-mentioned gas in rooms where
the oor is at a lower quota than the country
level).
ATTENTION:
if installing a kit or servicing the ap-
pliance, always empty the system’s
domestic hot water circuit rst so as not to
compromise the appliance’s electrical safety
(Par. 2.10).
Before installing the appliance, ensure that it is de-
livered in perfect condition; if in doubt, contact the
supplier immediately. Packing materials (staples, nails,
plastic bags, polystyrene foam, etc.) constitute a hazard
and must be kept out of the reach of children.
If the appliance is installed inside or between cabinets, ensure
sucient space for normal servicing; for the minimum instal-
lation distances refer to Fig. 3.
It is just as important that the intake grids and exhaust
terminals are not obstructed.
It is recommended to check that no ue gas recircula-
tion is found in the air sample points (0.5% maximum
permitted CO
2
).
Keep all ammable objects away from the appliance (paper,
rags, plastic, polystyrene, etc.).
e minimum distance for exhaust pipes from ammable
materials must be at least 25 cm.
Do not place household appliances underneath the boiler as
they could be damaged if the safety valve intervenes, if the
drain trap is blocked, or if there are leaks from the hydraulic
connections; otherwise, the manufacturer cannot be held re-
sponsible for any damage caused to the household appliances.
For the aforementioned reasons, we recommend not placing
furnishings, furniture, etc. under the boiler.
In the event of malfunctions, faults or incorrect operation, turn
the appliance o immediately and contact an authorised com-
pany (e.g. the Authorised Technical Assistance centre, which
has specically trained sta and original spare parts). Do not
attempt to modify or repair the appliance alone.
Any modication to the appliance that is not explicitly indicated
in this section of the booklet is forbidden.
Installation Standards:
- is boiler can be installed outdoors,
without additional protections.
- Installation of gas appliances, ue exhaust
pipes and combustion air intake pipes is for-
bidden in places with a re risk (for example:
garages, closed parking stalls), and in poten-
tially dangerous places.
- Installation is prohibited on the vertical pro-
jection of the cooking surface.
- Installation is forbidden in places/rooms that
constitute public areas of apartment build-
ings, internal stairways or other escape routes
(e.g. oor landings, entrance halls, etc.).
- Installation is also forbidden in places/rooms
that constitute public areas of apartment
buildings such as cellars, entrance halls, at-
tics, los, etc., unless otherwise provided for
by local regulations in force.
- ese boilers are not suitable for installation
on walls made of combustible material.