Infinitely Variable Change of Numeric Data Value
If the chosen parameter represents a numeric data value,
select a digit by means of the [
] [] navigation keys.
Change the selected digit infinitely variably by means of
the [] [] navigation keys. The chosen digit is indicated
by the cursor. Place the cursor on the digit you want to
save and press [OK].
Changing a Data Value, Step-by-Step
Certain parameters can be changed step by step or
infinitely variably. This applies to Motor Power (par. 1-
20), Motor Voltage (par. 1-22) and Motor Frequency (par.
1-23). The parameters are changed both as a group of
numeric data values and as numeric data values infinitely
variably.
Read-out and Programming of Indexed Parameters
Parameters are indexed when placed in a rolling stack.
Par. 15-30 to 15-32 contain a fault log which can be read
out. Choose a parameter, press [OK], and use the [
]
[
] navigation keys to scroll through the value log.
Use par. 3-10 as another example: Choose the
parameter, press [OK], and use the [] [] navigation
keys to scroll through the indexed values. To change the
parameter value, select the indexed value and press
[OK]. Change the value by using the [
] [] keys. Press
[OK] to accept the new setting. Press [CANCEL] to abort.
Press [Back] to leave the parameter.