39
SECTION 8 — PART LIST
Ingersoll Rand 302 Series VFD Part Number
Example: MODEL #: IRV302P75KT5E21H2XGX3XXSXXXXAXBXCXXXD0
[IRV302P] [75K] [T5] [E21] [H2] [X] [G] [X] [3] [XX] [SXXXX] [AX] [BX] [CXXX] [D0]
[IRV302P] Series
[75K] Power Size
75K=75kW (See Chart Below for Sizes)
[T5] AC Line Voltage
T2: 3 phase 200 240 Vac
T5: 3 phase 380 500 Vac
T6: 3 phase 525 - 600 Vac
T7: 3 phase 525 690 Vac
[E21] Enclosure
E20 IP20/ Chassis
E21 IP21/ NEMA 1
E54 IP54/ NEMA 12
[H2] [X] [G] [X] [3] Drive Options
H2 RFI Filter, 1=Integral class A1 and B1 RFI filter or 2=Integral class A2 RFI filter
X Dynamic Brake X none, B with
G Display X=None, G=Graphical, N=Numerical
X Coating X no, or C coated
3 Mains input X none, 3 with fused disconnect switch
[XX] Reserved
[SXXXX] Software Revision
[AX] [BX] [CXXX] [D0] Option Cards
A Field Bus X-none, 0-Profibus, 4-DeviceNet
B Extra I/O X-none, 2-Encoder, 5-Relays
C SyncPos Module
D External 24Vdc X-none, 0- with
Hp to kW Chart
Model
Hp
kW
Model
Hp
kW
Model
Hp
kW
0.25
0.18
5K5
7.5
5.5
75K
100.0
75.0
K25
0.33
0.25
7K5
10.0
7.5
90K
125.0
90.0
K37 0.50 0.37 11K 15.0 11.0 110 150.0 110.0
K55 0.75 0.55 15K 20.0 15.0 132 200.0 132.0
K75
1.0
0.75
18K
25.0
18.5
160
250.0
160.0
1K1
1.5
1.1
22K
30.0
22.0
200
300.0
200.0
1K5
2.0
1.5
30K
40.0
30.0
250
350.0
250.0
2K2
3.0
2.2
37K
50.0
37.0
315
450.0
315.0
3K7
5.0
3.7
45K
60.0
45.0
355
500.0
355.0
4K0 5.0 4.0 55K 75.0 55.0
The Drive can control 4 sizes smaller than the original model HP size.
Example: 75Hp [55kW] IRV302 can control a 30Hp [22kW] motor