SECTION 8 — PART LIST
Ingersoll Rand 302 Series VFD Part Number
Example: MODEL #: IRV302P75KT5E21H2XGX3XXSXXXXAXBXCXXXD0
[IRV302P] [75K] [T5] [E21] [H2] [X] [G] [X] [3] [XX] [SXXXX] [AX] [BX] [CXXX] [D0]
[IRV302P] Series
[75K] Power Size
75K=75kW (See Chart Below for Sizes)
[T5] AC Line Voltage
T2: 3 phase 200 – 240 Vac
T5: 3 phase 380 – 500 Vac
T6: 3 phase 525 - 600 Vac
T7: 3 phase 525 – 690 Vac
[E21] Enclosure
E20 IP20/ Chassis
E21 IP21/ NEMA 1
E54 IP54/ NEMA 12
[H2] [X] [G] [X] [3] Drive Options
H2 RFI Filter, 1=Integral class A1 and B1 RFI filter or 2=Integral class A2 RFI filter
X Dynamic Brake X none, B with
G Display X=None, G=Graphical, N=Numerical
X Coating X no, or C coated
3 Mains input X none, 3 with fused disconnect switch
[XX] Reserved
[SXXXX] Software Revision
[AX] [BX] [CXXX] [D0] Option Cards
A – Field Bus X-none, 0-Profibus, 4-DeviceNet
B – Extra I/O X-none, 2-Encoder, 5-Relays
C – SyncPos Module
D – External 24Vdc X-none, 0- with
Hp to kW Chart
4K0 5.0 4.0 55K 75.0 55.0
The Drive can control 4 sizes smaller than the original model HP size.