Control Commands
Command Return Value Description
ST 1 Stops all movements in all connected devices
BA 1 Moves until the upper limit is reached (positive direction)
(X-Axis)
FO 1 Moves until the lower limit is reached
(X-Axis)
CW 1 Moves clockwise until the limit is reached
(Azimuth-Axis)
CC 1 Moves anticlockwise until the limit is reached
(Azimuth-Axis)
LD ppp CM NP 1 Load ppp cm in Register NP (New Position)
(X-Axis)
LD nnn DG NP 1 Load nnn degrees in Register NP (New Position)
(Azimuth-Axis)
GO 1 Moves the selected axis to NP
© innco systems GmbH Schwarzenfeld/Germany
Erlenweg 12, 92521 Schwarzenfeld/Germany Phone: +49 9435 301659 0 Fax: +49 9435 301659 99
Email: info@inncosystems.com