When the update is complete the “Play” button will illuminate green and the BV30 will restart. Allow 30 seconds
after the BV30 restarts before disconnecting it from the DA3.
If the programming fails, the “Play” button will illuminate red. The Match Download LED or Override Download LED
(depending on the download type) will flash a to indicate the failure reason. This will be one long flash, followed by
a number of short flashes, explained in the table below:
Number of Short Flashes Failure Reason Resolution
2
No Validator Connection Found Check that the BV30 is in SSP
mode and is connected to the
“Validator” side of the DA3.
3
No Valid Download Files Found
If performing a Match update,
the file on the DA3 does not match
the file on the BV30.
If performing an Override
update, the file on the DA3 is not
compatible with the BV30.
4 Download Fail Retry the download.
Remote Updates
The BV30 supports remote updates via the SSP Protocol. Refer to the SSP implementation guide for information on
this remote update process.
This is a complex operation and incorrect implementation may damageunits.