IS580 User Manual Chapter 9 Function Code Table
- 107 -
Function
Code
Name LED Display Setting Range Min. Unit Default Property
A3-02
System oil pressure System oil pressure 0.0 kg/cm
2
to maximum oil
pressure (A3-03)
0.0 kg/cm
2
175.0 kg/
cm
2
A3-03 Max. oil pressure Max. oil pressure System oil pressure (A3-02)
to 500.0 kg/cm
2
0.0 kg/cm
2
250.0 kg/
cm
2
A3-04 Oil pressure reference
ramp time
Oil pressure reference
ramp time
0s to 2s 0.001s 0.020s
A3-05 Oil pressure control
Kp1
Oil pressure control Kp1 0.0 to 800.0 0.1 210.0
A3-06 Oil pressure control Ti1 Oil pressure control Ti1 0.001s to 10.000s 0.001s 0.100s
A3-07 Oil pressure control Td1 Oil pressure control Td1 0.000s to 1.000s 0.001s 0.000s
A3-08 Max. reverse rotational
speed
Max. reverse rotational
speed
0.0% to 100.0% 0.1% 20.0%
A3-09 Min. ow Min. ow 0.0% to 50.0% 0.1% 0.5%
A3-10 Min. pressure Min. pressure 0.0 to 50.0 kg/cm
2
0.1 kg/cm
2
0.5 kg/cm
2
A3-11 Oil pressure control
Kp2
Oil pressure control Kp2 0.0 to 800.0 0.1 210.0
A3-12 Oil pressure control Ti2 Oil pressure control Ti2 0.001s to 10.000s 0.001s 0.100s
A3-13 Oil pressure control Td2 Oil pressure control Td2 0.000s to 1.000s 0.001s 0.000s
A3-14 Oil pressure control
Kp3
Oil pressure control Kp3 0.0 to 800.0 0.1 210.0
A3-15 Oil pressure control Ti3 Oil pressure control Ti3 0.001s to 10.000s 0.001s 0.100s
A3-16 Oil pressure control Td3 Oil pressure control Td3 0.000s to 1.000s 0.001s 0.000s
A3-17 Oil pressure control
Kp4
Oil pressure control Kp4 0.0 to 800.0 0.1 210.0
A3-18 Oil pressure control Ti4 Oil pressure control Ti4 0.001s to 10.000s 0.001s 0.100s
A3-19 Oil pressure control Td4 Oil pressure control Td4 0.000s to 1.000s 0.001s 0.000s
A3-20 AI zero drift auto
correction
AI zero drift auto
correction
0: Disabled
1: Enabled
0 0
A3-21 Fault detection time of
oil pressure sensor
Fault detection time of
oil pressure sensor
0.000s: Detection invalid
0.001s to 60.000s
0.001s 0.500s
A3-22 Setting of max. speed
in pressure control
Setting of maximum
speed in pressure
control
0.0%–100.0% 0.1% 10.0%
A3-23 Setting of min. oil
pressure in pressure
control
Setting of min. oil
pressure in pressure
control
0.0% to 100.0% 0.1% 60.0%
A3-24 Delay of pressure
control state output
Delay of pressure
control state output
0.000s to 10.000s 0.001s 0.100s
A3-25 S-curve rise lter time
of set oil pressure
S-curve rise lter time of
set oil pressure
0.000s to 1.000s 0.001s 0.040s