EasyManua.ls Logo

Inovance IS580 Series - Page 110

Inovance IS580 Series
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Function Code Table IS580 User Manual
- 108 -
Function
Code
Name LED Display Setting Range Min. Unit Default Property
A3-26
S-curve fall lter time of
set oil pressure
S-curve fall lter time of
set oil pressure
0.000s to 1.000s 0.001s 0.020s
A3-27 Overshoot suppression
detection level
Overshoot suppression
detection
0 to 2000 1 200
A3-28 Overshoot suppression
coefcient
Overshoot suppression
coefcient
0 to 3.000 0.001 0.200
A3-29 Oil pressure loop gain
coefcient
Oil pressure loop gain
coefcient
0.20 to 5.00 0.01 1.00
A3-30 Torque upper limit
for switchover from
pressure mode to
speed mode
Torque upper limit
for switchover from
pressure mode to speed
mode
50.0%–250.0% 0.1% 160.0%
A3-31 Injection valve opening
delay
Injection valve opening
delay
0.020s to 0.500s 0.001s 0.100s
A3-32 Slave min. input Slave min. input 0.0% to A3-34 0.1% 0.0%
A3-33 Corresponding setting
of slave min. input
Corresponding setting
of slave min. input
-100.0% to 100.0% 0.1% 0.0%
A3-34 Slave medium input Slave medium input A3-32 to A3-36 0.1% 0.0%
A3-35 Corresponding setting
of slave medium input
Corresponding setting
of slave medium input
-100.0% to 100.0% 0.1% 0.0%
A3-36 Slave max. input Slave max. input A3-34 to 100.0% 0.1% 100.0%
A3-37 Corresponding setting
of slave max. input
Corresponding setting
of slave max. input
-100.0% to 100.0% 0.1% 100.0%
A3-38 Master judges whether
to send slave speed
enabled in multi-pump
mode
Master judges whether
to send slave speed
enabled in multi-pump
mode
0: Forbid enabling the slave
speed
1: Allow enabling the slave
speed
1 0
A3-39 Pressure holding
control gain in multi-
pump convergent ow
Pressure holding control
gain in multi-pump
convergent ow
20 to 800 1 100
A3-40 Pressure deviation for
decreasing PI to de-
twitter in multi-pump
injection mode
Pressure deviation for
decreasing PI to de-
twitter in multi-pump
injection mode
0.0 to 50.0 kg 0.1 kg 5.0 kg
A3-41 Flow lower limit for
decreasing PI to de-
twitter in multi-pump
injection mode
Flow lower limit for
decreasing PI to de-
twitter in multi-pump
injection mode
0 to 30000 rpm 1 rpm 0 rpm
A3-42 Flow detection time for
decreasing PI to de-
twitter in multi-pump
injection mode
Flow detection time for
decreasing PI to de-
twitter in multi-pump
injection mode
0.200s to 2.000s 0.001s 0.400s