- 109 -
Function
Code
Name LED Display Setting Range Min. Unit Default Property
A3-43
Pressure deviation of
slave pump not working
in the CAN multi-pump
mode
Pressure deviation of
slave pump not working
in the CAN multi-pump
mode
0 to 50.0 kg 0.1 kg 5.0 kg
☆
A3-44 Flow lower limit of slave
pump not working
Flow lower limit of slave
pump not working in the
CAN multi-pump mode
-100.0% to 100.0% 0.0% 0
☆
A3-45 Judgment delay of
slave pump to stop
without speed reference
Judgment delay of slave
pump to stop without
speed reference
0.100s to 5.000s 0.001s 1.000s
☆
A3-46 Deceleration time of
slave pump to stop
without speed reference
Deceleration time of
slave pump to stop
without speed reference
0.001s to 5.000s 0.001s 0.200s
☆
A3-47 Start valve pressure
relief delay
Start valve pressure
relief delay
0.001s to 5.000s 0.001s 0.100s
☆
A3-48 Exit valve pressure
relief delay
Exit valve pressure relief
delay
0.001s to 5.000s 0.001s 0.100s
☆
A3-49 Pressure deviation
lower limit of start valve
pressure relief
Pressure deviation
lower limit of start valve
pressure relief
0.0 kg to A3-02 (System oil
pressure)
0.1 kg 0.0 kg
☆
A3-50 Pressure lower limit of
start valve pressure
relief
Pressure lower limit of
start valve pressure
relief
0.0 kg to A3-02 (System oil
pressure)
0.1 kg 0.0 kg
☆
A3-51 Pressure sensor fault
detection current lower
limit
Pressure sensor fault
detection current lower
limit
0% to 300% (rated motor
current F1-03)
1% 100%
☆
A3-52 Pressure sensor fault
detection speed upper
limit
Pressure sensor fault
detection speed upper
limit
0% to 100% (max. motor
speed A3-01)
1% 50%
☆
Group A4: Oil Pressure Control Optimization Parameters
A4-00 Rotational speed lter
time
Rotational speed lter
time
0s to 5.000s 0.001s 0.005s
☆
A4-01 Current lter time Current lter time 0s to 5.000s 0.001s 0.010s
☆
A4-02 Reserved - - - -
☆
A4-03 Flow rise lter time Flow rise lter time 0s to 1.000s 0.001s 0.100s
☆
A4-04 Flow fall lter time Flow fall lter time 0s to 1.000s 0.001s 0.100s
☆
A4-05 Reserved - - - -
☆
A4-06 Flow leakage
compensation
Flow leakage
compensation
0.0% to 50.0% 0.1% 0.0%
☆
A4-07 Reserved - - - -
☆
A4-08 Min. pressure of
reverse pressure relief
Min. pressure of reverse
pressure relief
0.0 kg/cm
2
to A3-02 0.1 kg/cm
2
0.0 kg/cm
2
☆