Function
code
Name LED display Set range
Minim-
um unit
Factory
default
value
Modication
description
F7-07
1 Radiator
temperature 1
Radiator
temperature 1
0.0
℃~
100
℃
1
℃
-
●
F7-08
Radiator
temperature 2
Radiator
temperature 2
0.0
℃~
100
℃
1
℃
-
●
F7-09
Accumulated
running time
Accumulated
running time
0h
~
65535h 1 -
●
F7-10
1 Software
version No.1
Software
version No.1
- - -
●
F7-11
Software
version No.2
Software
version No.2
- - -
●
Group F8 Auxiliary Function
F8-00
Jog running
frequency
Jog running
frequency
0.00Hz ~ maximum frequency 0.01Hz 2.00Hz
☆
F8-01
Jog speed-up
time
Jog speed-up
time
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-02
Jog speed-
down time
Jog speed-
down time
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-03
Speed-up
time 2
Speed-up time
2
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-04
Speed-down
time 2
Speed-down
time 2
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-05
Speed-up
time 3
Speed-up time
3
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-06
Speed-down
time 3
Speed-down
time 3
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-07
Speed-up
time 4
Speed-up time
4
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-08
Speed-up
time 4
Speed-up time
4
0.0s
~
6500.0s 0.1s 20.0s
☆
F8-09
Skip
frequency 1
Skip frequency
1
0.00Hz ~ maximum frequency 0.01Hz 0.00Hz
☆
F8-10
Skip
frequency 2
Skip frequency
2
0.00Hz ~ maximum frequency 0.01Hz 0.00Hz
☆
F8-11
Skip
frequency
amplitude 1
Skip frequency
amplitude 1
0.00Hz ~ maximum frequency 0.01Hz 0.01Hz
☆
F8-12
Forward/
reverse
rotation dead-
zone time
Forward/
reverse
rotation dead-
zone time
0.0s
~
3000.0s 0.1s 0.0s
☆
F8-13
Reverse
control
Reverse
control
0: Reverse rotation enabled
1: Reverse rotation disable
1 0
☆