Quick Operation
‑42‑
Pa
rame
ter
Cod
e
Parameter
Name
De
fault
Value Range
Description
b6‐
00
Main
frequency
source
0
0: Digital setting
2: AI1
0: Digital setting
The initial frequency is used as the
main frequency. The frequency can
be changed by using the ▲ and ▼
keys on the operating panel or the
multi‑functional input terminal
functioning as the UP/DOWN key.
When the AC drive is powered off
and then powered on, whether the
frequency adjusted by using UP/
DOWN keys or multi‑functional input
terminal functioning as the UP/
DOWN key is saved depends on the
configuration of "retain values set by
using UP/DOWN keys or multi‑
functional input terminal functioning
as the UP/DOWN key". The "clear
values adjusted by using UP/DOWN
keys or multi‑functional input
terminal functioning as the UP/
DOWN key" function of the DI allows
you to clear values set by using UP/
DOWN keys or multi‑functional input
terminal functioning as the UP/
DOWN key.
2: AI1
The frequency reference is
calculated based on current or
voltage signals input through AI1
and the preset AI curve.