Introduction
-
10
-
Function Description Remarks
Energy-saving Functions
Car energy-
saving
In car door open holding and door close limit state, after the set time (F9-01)
fan in the car.
F9-01 "Time for
fan and lamp
to be turned
Energy-saving
running with
standby power
supply
When the normal power supply is interrupted and the emergency power
supply is used, the system reduces the running speed of the elevator in the
prerequisite of guaranteeing the smooth running curve.
-
Arrival gong
disabled at night
Within the set time period, the arrival gong is disabled. Bit4 of F5-33
2 Optional functions
Function Function description Remarks
Door pre-open
function
In automatic running state, when the elevator speed is smaller than 0.25 m/s
and the door zone signal is active, the system shorts the door lock by means
of the shorting door lock circuit relay and outputs the door open signal,
MCTC-SCB
required
Micro-leveling
the load change and the car door is not aligned with the ground, which is
inconvenient for passengers and goods in and out. In this case, the system
allows the elevator to run to the leveling position in the door open state at the
re-leveling speed.
MCTC-SCB
required
Power failure
emergency
evacuation
the emergency power supply to implement low-speed self-rescue in the case
of power failure.
MCTC-ARD-C
required
Onsite
commissioning
Function
The system can control and monitor running of elevators by using the NEMS
software.
-
Commissioning
by cell phone
The smartphone can be connected to the controller through the external WIFI
module, and you can commission the elevator, and upload and download
parameters by using the cell phone.
Special WIFI
module and
cell phone
host computer
required
Residential
monitoring
The control system can be connected to the terminal in the monitoring
direction, and fault state of the elevator.
NEMS software,
accessories,
and MCTC-MIB
required
IC card IC card required
STO
When a fault is detected in the safety circuit, the STO function safety card acts
torque of the motor.
Special bottom
and STO
function card
MCTC-JCB-A2
required
Machine-room-
less monitoring
The running state of the elevator inside the shaft is displayed and the function
of commissioning and burning outside the shaft is implemented through the
MCTC-MB-A2 monitoring board.
MCTC-MB-A2
monitoring
board required