5 System Commissioning
-
176
-
󶙯󶍿
󶍿󶙮
car arrival. Otherwise, although you have adjusted the leveling accuracy by setting
group Fr parameters, the elevator may still stop outside the leveling zone.
B
A
Down
leveling
signal
Up leveling
signal
Car sill
Hall sill
Car
Leveling
plate
󶙽Leveling distance diagram
󶍾󶍿󶍽
and height deviation between the car position and the hall sill are inconsistent at the
󶍿-
ters). To solve the problem, increase the speed loop proportional gain or decrease the
speed loop integral time properly.