6 Parameter Description
-
184
-
Function
Code
Name Setting Range Default Unit Property
F0-07 Carrier frequency 0.5 to 16.0 6.0 kHz
It is used to set the carrier frequency of the controller.
The carrier frequency is closely related to the motor noise during running. When
it is generally set above 6 kHz, mute running is achieved. It is recommended to set
the carrier frequency to the lowest within the allowable noise, which reduces the
controller loss and radio frequency interference.
When the carrier frequency reduces, the following factors also increase:
Higher harmonics of output current
Motor power loss
Motor temperature rise
When the carrier frequency increases:
Motor power loss and temperature rise declines.
Power loss, system temperature rise and interference increase.
󶍿
following table.
Carrier frequency Low to High
Motor noise Large to Small
Output current
waveform
Bad to Good
Motor temperature
rise
High to Low
Controller
temperature rise
Low to High
Leakage current Small to Large
External radiation
interference
Small to Large