6 Parameter Description
-
204
-
■
16: Higher-voltage startup of brake
This signal is used for the brake that keeps the release state with voltage reduction.
The terminal with this signal keeps the output for 4s to release the brake, and then the
voltage is reduced to keep the brake release state.
■
17: Elevator running in up direction
The terminal with the signal has output when the elevator runs in the up direction.
■
18: Lamp/Fan running
It is used for the lamp/fan running output, the same as the energy saving control
output of the CTB.
■
19: Medical sterilization
It is used to control the output of the ultraviolet sterilizing lamp signal. After the
elevator stops running and the lamp/fan stops operating, the medical sterilization
output is started.
■
20: Non-door zone stop
The terminal with this signal has output when the elevator stops at the non-door
zone.
■
21: Electric lock
It is used to control applying and releasing of the electric lock in the case of manual
door.
■
22: Non-service state
It is output when the elevator is in the non-service state and cannot respond to hall
calls.
■
23: Emergency evacuation completed
Output after emergency evacuation is completed. It is used to notify that ARD
emergency evacuation is completed.
■
25: Wire holder resetting
Wire holder resetting output conditions (meeting any of the following):
1)
circuit fault) are not reported after 5-second delay (wire holder power-on time).
2) E67 is reported, but E65 (UCMP fault) is not reported. Under the inspection state,
the safety circuit is disconnected (E41 safety circuit fault is reported) and then
connected.
Wire holder resetting output requirements:
1) The wire holder resetting output signal is valid. Check whether the wire holder
feedback signal is valid.
a) If the wire holder feedback signal is valid for one second or longer, clear E67. The
status of the wire holder resetting output signal changes from valid to invalid, and
the elevator works properly.
b) If the wire holder feedback signal is still invalid after 22 seconds (wire holder
starting time), E67 persists. The status of the wire holder resetting output signal