6 Parameter Description
-
242
-
Function
Code
Name Setting Range Default Unit Property
FA-38
time interval
0 to 200 0 s
reference time for motor running protection time. If the leveling signal does not
change within the reference time in running, the system report the fault E30 and the
elevator stops running.
Function
Code
Name Setting Range Default Unit Property
FA-46 Hall call communication state 1 0 to 65535 0 -
FA-47 Hall call communication state 2 0 to 65535 0 -
FA-48 Hall call communication state 3 0 to 65535 0 -
FA-50
Expansion board hall call
communication state 1
0 to 65535 0 -
FA-51
Expansion board hall call
communication state 2
0 to 65535 0 -
FA-52
Expansion board hall call
communication state 3
0 to 65535 0 -
MCB.
FA-46 to FA-48 display the communication state between the MCB Modbus interface
and the HCB.
FA-50 to FA-52 display the communication state between the equipment room
expansion board and the HCB.
States 1, 2, and 3 respectively correspond to the hall call communication state of
viewing the state.
A
B
C
D
E
F
G
DP
5
4 3
2
A
B
C
D
E
F
G
DP
1
Hall call floor
State
Each segment indicates
a hall call floor
Hall call communication state