6 Parameter Description
-
244
-
Function
Code
Name Setting Range Default Unit Property
Fb-02 󶍿 0 to 65535 65535 -
Fb-03 󶍿 0 to 65535 65535 -
Fb-18 󶍿 0 to 65535 65535 -
Fb-04 󶍿 0 to 65535 65535 -
Fb-05 󶍿 0 to 65535 65535 -
Fb-19 󶍿 0 to 65535 65535 -
󶍿
machine 2.
󶍿󶍿
󶍿󶍿
󶍿󶍿
󶍿
󶍿
󶍿
Function
Code
Name Setting Range Default Unit Property
Fb-06 Door open protection time 5 to 99 10 s
Fb-07 Arrival gong output delay 0 to 1000 0 ms
Fb-08 Door close protection time 5 to 99 15 s
Fb-06 is used to set the door open protection time.
After outputting the door open command, if the system does not receive the door
open limit signal after the time set in this parameter, the system re-opens the door.
When the door open/close times reach the value set in Fb-09, the system reports fault
E48.
Fb-07 is used to set the arrival gong output delay.
When the value of this parameter is larger than 10 and the car display is switched over
󶍿
parameter. If the value is smaller than 10, the system outputs the arrival gong at stop.
Fb-08 is used to set the door close protection time.
After outputting the door close command, if the system does not receive the door
close limit signal after the time set in this parameter, the system re-closes the door.
When the door open/close times reach the value set in Fb-09, the system reports fault
E49.