7 Troubleshooting
-
278
-
Fault
Code
Name Possible Causes Solution Level
Err36
RUN contactor
feedback
abnormal
Subcode 101: The feedback of
the RUN contactor is active,
but the contactor has no
output.
Check whether the feedback contact of the
contactor acts properly.
Check the signal feature (NO, NC) of the
feedback contact.
5A
Subcode 102: The controller
outputs the RUN signal but
receives no RUN feedback.
Subcode 104: When both
feedback signals of the RUN
contactor are enabled, their
states are inconsistent.
Subcode 105: The feedback
of the RUN contactor is active
before re-leveling is enabled.
Subcode 103: The current of
the asynchronous motor from
the acceleration segment to
the constant speed segment is
 󶙮
Check whether the output cables UVW of the
controller are connected properly. Check
whether the control circuit of the RUN con-
tactor coil is normal.

Table of Contents