7 Troubleshooting
-
285
-
Fault
Code
Name Possible Causes Solution Level
Err67 AFE fault
Subcode 01: Overcurrent
Check whether the grounding or short circuit
of the AFE or AC drive exists.
Check whether the controller parameters are
set unreasonably.
Check whether the power grid is abnormal
and whether output oscillation exists.
Check any internal fault of the machine.
Contact Inovance.
5A
Subcode 02: AFE overheat
Subcode 04: Bus undervoltage
Check whether the ambient temperature is
too high.
Check whether the fan is faulty and whether
󶍾
Check whether the module is damaged.
Test the circuit fault. Contact Inovance.
Reduce the load if the load is too heavy.
Check whether the bus voltage test is abnor-
mal. Contact Inovance.
Subcode 06: Bus overvoltage
Install a regen. resistor on the AC drive.
Check whether the power grid voltage and
wiring are normal.
Check model matching and conditions.
Contact Inovance. Check whether the circuit
and the voltage loop are set reasonably.
Subcode 07: AFE overload
Check whether the matching of the machine
power is reasonable.
Subcode 08: Power grid
overvoltage
Subcode 09: undervoltage of
the mains
Subcode 10: overfrequency of
the mains
Subcode 11: underfrequency
of the mains
Check whether the power grid voltage is
normal.
Contact Inovance. Check whether the circuit
is normal.