Appendix B Parameter Table
-
363
-
Function
Code
Name Setting Range Default Unit Property Page
FE-33 Elevator function selection 2
Bit1: Door open holding at open limit
Bit2: Door close command not output upon
door close limit
Bit4: Auto reset for RUN and brake contactor
stuck
Bit5: Slow-down switch stuck detection
Bit7: Forced door close
Bit15: Opposite door independent control
36 -
P255
to
P256
FF: Factory Parameters
FJ: Factory Parameters
Group FP: User parameters
FP-00 User password
0: No password
01 to 65535
0 -
P257FP-01 Parameter update
0: No operation
1: Restore default setting (except group F1)
2: Clear fault records
3: Clear shaft data
0 -
FP-02
󶍾
display
0: Invalid
1: Valid
0 -
FP-05 Contract No. 2 0 to 65535 0 -
P258
FP-06 Contract No. 1 0 to 65535 5555 -
Group Fr: Leveling adjustment parameters
Fr-00 Leveling adjustment function
0: Invalid
1: Enabled
0 -
P258
to
P259
Fr-01 Leveling adjustment record 1 0 to 60060 30030 mm
to to 0 to 60060 30030 mm
Fr-20 Leveling adjustment record 20 0 to 60060 30030 mm
Group E0: Details of last group of faults
E0-00 Last fault code 0 to 9999 0
P259
to
P260
E0-01 Last fault subcode 0 to 65535 0
E0-02 Last fault month and day 0 to 1231 0 MM.DD
E0-03 Last fault hour and minute 0 to 23.59 0 HH.MM
E0-04 Last fault logic information 0 to 65535 0
E0-05 Last fault curve information 0 to 65535 0
E0-06 Speed reference upon last fault 0.000 to 4.000 0 m/s
E0-07 Feedback speed upon last fault 0.000 to 4.000 0 m/s
E0-08 Bus voltage upon last fault 0 to 999.9 0 V
E0-09 Present position upon last fault 0.0 to 300.0 0 m
E0-10 Output current upon last fault 0.0 to 999.9 0 A
E0-11
Output frequency upon last
fault
0.00 to 99.99 0 Hz
E0-12 Torque current upon last fault 0.0 to 999.9 0 A
E0-13 Output voltage upon last fault 0 to 999.9 0 V
E0-14 Output torque upon last fault 0 to 200.0 0 %
E0-15 Output power upon last fault 0.00 to 99.99 0 kW
P261
E0-16
Communication interference
upon last fault
0 to 65535 0
E0-17
Encoder interference upon last
fault
0 to 65535 0
E0-18 Input state 1 upon last fault 0 to 65535 0
E0-19 Input state 2 upon last fault 0 to 65535 0
E0-20 Input state 3 upon last fault 0 to 65535 0
E0-21 Input state 4 upon last fault 0 to 65535 0
E0-22 Input state 5 upon last fault 0 to 65535 0
E0-23 Output state 1 upon last fault 0 to 65535 0
E0-24 Output state 2 upon last fault 0 to 65535 0
E0-25 Car input state upon last fault 0 to 65535 0
E0-26 Car output state upon last fault 0 to 65535 0
E0-27 Hall call state upon last fault 0 to 65535 0
E0-28 System state 1 upon last fault 0 to 65535 0
P260
E0-29 System state 2 upon last fault 0 to 65535 0

Table of Contents