Chapter 4 Operation and Trial Running
- 26 -
Figure 4-3 Example of editing function code
F015.00
PRG
F000
00.00
PRG
PRG
ENTER
ENTER
ENTER
PRG
F005
15.00
F004
Status parameter
(default display)
To save the
setting
If there is a blinking digit,
press / / to modify the digit.
In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot be
modied. This may be because:
•
Such a function code is only readable, such as actually detected parameter and running
record parameter.
•
Such a function code cannot be modied in the running state and can only be changed at
stop.
4.2.2 Viewing Fault Information
When a fault occurs on the controller, the operation panel displays the fault code, based on
which, you can nd the cause of the fault and rectify the fault quickly.
The controller saves the last four fault codes, and details of the frequency, current, bus voltage
and DI/DO status at the latest fault are recorded.