Chapter 6 Description of Function Codes
- 87 -
Function Code Parameter Name Setting Range Default Min. Unit
FA-26 High bits of current door position 0–9999 0 1
The two parameters record the current door position.
Current door position = FA-26 x 10000 + FA-25
Function Code Parameter Name Setting Range Default Min. Unit
FA-27 Door machine state display 0–9999 0 1
It is used to view the state of the door machine, such as door open, door close, or running.
Function Code Parameter Name Setting Range Default Min. Unit
FA-28 Door direction judgment * * *
It is used to detect the signal wiring of the encoder AB phase.
If "OPEN" is displayed when you manually pull the door to the open direction, it indicates
that the AB phase signal wiring is correct. Otherwise, the AB phase signal is abnormal.
If "CLOSE" is displayed when you manually pull the door to the close direction, it indicates
that the AB phase signal wiring is correct. Otherwise, the AB phase signal is abnormal.
Group FP: User Parameters
Function Code Parameter Name Setting Range Default Min. Unit
FP-00 User password 0–9999 0 1
It is used to set the user password.
If it is set to any non-zero number, the password protection function is enabled. After a
password has been set and taken effect, you must enter the correct password in order to enter
the menu. If the entered password is incorrect, you cannot view or modify parameters.
If FP-00 is set to 00000, the previously set user password is cleared, and the password
protection function is disabled.
Remember the password that you set. If the password is set incorrectly or forgotten, contact
Inovance to replace the control board.
Function Code Parameter Name Setting Range Default Min. Unit
FP-01 Parameter update 0–2 0 1
0: No function
1: Restore the default setting
2: Clear fault records and time