EasyManua.ls Logo

Inovance NICE900 Series - Converting Binary Value of FA-00 to Decimal

Inovance NICE900 Series
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Description of Function Codes
- 82 -
the running state.
FA-00 includes 9 binary bits, each dening a parameter. A total of 9 parameters can be can be
displayed during running.
The 9 binary bits correspond to the running parameters listed in the following table.
Bit Parameter Name Default
Bit0 Frequency reference 1
Bit1 Running frequency 1
Bit2 Bus voltage 1
Bit3 Output voltage 1
Bit4 Output current 1
Bit5 Output torque 1
Bit6 Input terminal state 0
Bit7 Output terminal state 0
Bit8 Door position pulse 1
The method of setting FA-00 is as follows:
If a bit is set to 1, the parameter indicated by this bit is displayed; if this bit is set to 0, the
parameter is not displayed.
Convert the sum of binary values of all 9 bits to decimal, and then set the decimal on the
operation panel.
Figure 6-9 Converting binary value of FA-00 to decimal
1
2
4
8
16
32
0
0
256
Bit2
Bit1
Bit3
Bit4
Bit5
Bit6
Bit7
Bit8
Bit0Bit1Bit2
Bit3Bit4Bit5Bit6Bit7Bit8
1612 248
16
3264128
Bit Addressing
Binary Addressing
Convert binary value to
decimal, and set this decimal
on the operation panel
Bit0
FA
-00
Display in running state
By default, all 16 parameters are displayed; therefore, the value set on the operation panel is:
1 + 2 + 4 +8+16+32+0+0+256 = 319
The method of viewing FA-00 is as follows: