Keypad
‑72‑
Figure 5‑13 Procedure for setting bus control forced DO function
When 200D.12h is set to 4, 60FE (Digital output) can be used to forcibly set the
DO terminal level through the bus, regardless of the internal DO status of the
drive.
bit Related DO
Output mask: 60FE.02h Physical output: 60FE.01h
16 DO1
1: DO3 forced output
enabled
DO1 forced output (0: OFF, 1:
ON)
17 DO2
1: DO3 forced output
enabled
DO2 forced output (0: OFF, 1:
ON)
18 DO3
1: DO2 forced output
enabled
DO3 forced output (0: OFF, 1:
ON)
When 200D.12h is set to 4 and any bit among bit16...bit18 of 60FE.02h is set to
1, the corresponding forced DO is OFF.
H0b.05 is used to monitor the DO level status. The keypad displays the level,
and the value of H0b.05 (monitored DO signal) read in the software tool is
hexadecimal.