38
• Press the Capture Gate Button or connect a gate signal to the
Capture Gate Input to start capturing audio.
• Capture will be activated until the maximum layer duration has been
met. If the Capture Gate Button is pressed while capture is activated,
or if the gate signal present at the Capture Gate Input is low,
recording will be stopped.
• Once capture has deactivated, turn the Input Level fully
anticlockwise. This effectively turns down the Condenser
Microphone input signal.
• Experiment with all granular and pitch knobs to find desired effects
and sweet spots.
Control Path:
• Apply control voltage to any of the CV inputs of arbhar.