1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
Intel Confidential 23
1000BASE-T MDI Return Loss
6 1000BASE-T MDI Return Loss
IEEE Standard 40.8.3.1
6.1 Test Purpose
To measure the return loss on all four channels at the MDI.
6.2 Specification
The return loss for each transmit/receive channel shall be:
16 dB from 1 MHz to 40 MHz, and
10 – 20LOG(f/80)dB from 40 MHz to 100 MHz, where f is in MHz.
6.3 Test Equipment
Vector network analyzer
BNC cable with 50-ohm characteristic impedance
UUT with gigconf.exe test software.
6.4 Test Fixtures
Fixture 40.8.3.1.A, Balun test fixture (Appendix A)
Fixture 40.8.3.1.B, calibration standards (Appendix A)
Fixture 40.8.3.1.C, square pin fixture (Appendix A)
6.5 Test Procedure
1. Connect the equipment as shown in the figure below. Note: do not connect test fixture
40.8.3.1.C to the UUT's RJ-45 at this time. See Appendix A for more details.