Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
57
5.2.1 2U 8x2.5” Intel® Accessory Kit A2U44X25NVMEDK SAS/SATA Cable Guide
Figure 13. Combo Backplane Module Placement 8 x 2.5” front drive configurations
System
Configuration
Drive Bay #1
Cables for On-board
Multi-port SATA
Ports to Backplane
Cables for
Mezzanine 12 Gb
SAS ROC Module to
Backplane
Cables for
Mezzanine 6 Gb SAS
RAID module to
Backplane
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Backplane
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Backplane
R2208WT…
Drive Bay #1
populated
8 x 2.5” Combo
SAS / SATA + PCIe*
SSD SFF (NVMe)
iPC
A2U44X25NVMEDK
PCIe* cables included
in accessory kit. For
SAS/SATA support
see the following
options
730 mm HD --- HD
Connect cable to:
SATA -> BP 0-3
Included w/system
SKUs
and / or
730 mm HR --- HD
Connect cable to:
sSATA -> BP 4-7
Included w/system
SKUs
Cable kit required for
building block
integration:
(2) AXXCBL730HDHD
Use PCIe* cables
included with Combo
backplane kit for PCIe*
SSD SFF / NVMe drive
support
730 mm HD --- HD
Connect cable to:
SAS Mezz -> BP 0-3
Included w/system
SKUs
and/or
730 mm HD --- HD
Connect cable to:
SAS Mezz -> BP 4-7
Included w/system
SKUs
Cable kit required for
building block
integration:
(2) AXXCBL730HDHD
Use PCIe* cables
included with Combo
backplane kit for PCIe*
SSD SFF / NVMe drive
support
730 mm HD --- MS
Connect cable to:
SAS Mezz -> BP 0-3
and/or
730 mm HD --- MS
Connect cable to:
SAS Mezz -> BP 4-7
Cable Kits Required:
(1 or 2)
AXXCBL730HDMS
Use PCIe* cables
included with Combo
backplane kit for PCIe*
SSD SFF / NVMe drive
support
From Riser #1
730 mm HD --- HD
Connect cable to:
SAS PCIe -> BP 0-3
and/or
730 mm HD --- HD
Connect cable to:
SAS PCIe -> BP 4-7
Cable Kits Required:
(1 or 2)
AXXCBL730HDHD
Use PCIe* cables included
with Combo backplane kit
for PCIe* SSD SFF / NVMe
drive support
From Riser #1
730 mm HD --- MS
Connect cable to:
SAS PCIe -> BP 0-3
and/or
730 mm HD --- MS
Connect cable to:
SAS PCIe -> BP 4-7
Cable Kits Required:
(1 or 2)
AXXCBL730HDMS
Use PCIe* cables
included with Combo
backplane kit for PCIe*
SSD SFF / NVMe drive
support

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600WT and is the answer not in the manual?

Intel S2600WT Specifications

General IconGeneral
BrandIntel
ModelS2600WT
CategoryServer Board
LanguageEnglish

Related product manuals