v240M – Marine Satellite Communication System
176
Environmental Test Specication
Test Intellian Standard Remark
Temperature
Operational: -25 °C ~ + 55 °C
Survival: -40 °C ~ + 80 °C
Storage: -40 °C ~ + 85 °C
Damp Heat
Preconditioning (3 hours (± 30 min.))
• Temp. : 25 °C ± 3 °C
• Humidity : more than 95 %
9 hours (± 30 min.) at 55 °C ± 2 °C/ 93 % ± 3 % (humidity)
3 to 6 hours temperature fall
9 to 6 hours at 25 °C ± 3 °C/ more than 95 % (humidity)
2 cycles
DNV
Dry Heat
Relative Humidity : Max. 55 %
16 hours at 55 °C + 2 hours at 70 °C
Tolerances: Temp : ± 2 °C
Humidity : ± 10 %
DNV
Salt Mist
Number of spraying : 4
Storage period in damp chamber : 7days after each spray-
ing, 28 days total
Spraying duration : 2 Hour
Temperature: 25 °C ±10°C
Saline solution: 5%NaCl, PH6.5 to 7.2 at 20°C ± 2°C
Storage temperature: 40 °C ±2°C
Humidity : in chamber during storage : 93% +2%/-3%
IEC-60068-2-52
DNV
Cold Test 2 hours at -40 °C ± 2 °C
Vibration MIL-STD-167A-1
Shock MIL-STD-810F
Water
Ingress
Resistant to water penetration sprayed from any direction
Standard: IPX6
IEC60945
Wind Speed 100 Knots
MTBF At least 40,000 hours
Compliances with Regulations
Standard
R&TTE
• Safety: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
• EMC: IEC 60945:2002, EN60945:2002, EN301 489-1:2011
FCC FCC Part 15:2010
Military Standards
MIL-STD-167A-1
MIL-STD-801F