7. The display will show ".". Press the PRINT/ACCUMULATE button. The
flashing digit shows the current setting. The number displayed is the number of
minutes the scale can remain idle before it automatically shuts down. Setting the
number to "" will disable the function and the scale will never automatically shut
down. Use the LOCAL/TOTAL button the advance the number and the ZERO button
to move the flashing number to the left. When the display shows the desired
number, press the PRINT/ACCUMULATE button.
8. The display will show "". Press the PRINT/ACCUMULATE button. The flashing
digit shows the current setting. The Print Mode setting enables one of three scale
print modes (0 for on-demand, 1 for continuous, 2 for accumulating total axle format
and 3 for accumulating total standard format). Use the LOCAL/TOTAL button to
increment and the ZERO button to decrement the number. When the display shows
the desired number, press the PRINT/ACCUMULATE button.
9. The display will show "". Press the PRINT/ACCUMULATE button. The flashing
display shows the current printer baud rate setting. The available baud rates are:
1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200. Use the LOCAL/TOTAL
button or the ZERO button to toggle through the available rates. When the desired
printer baud rate setting is shown, press the PRINT/ACCUMULATE button.
10.The display will show "". Press the PRINT/ACCUMULATE button. The current
unit of measure (lb or kg) icon will flash in the upper left corner of the display. The
Measurement Units function will set the scale to measure in pounds (lb) or kilograms
(kg). Use the LOCAL/TOTAL button or the ZERO button to toggle between the two
settings. When the desired setting is flashing, press the PRINT/ACCUMULATE
button.
11.The display will show the message "". Press the PRINT/ACCUMULATE
button. The flashing display shows the current Protocol setting. There are four
protocol settings available to choose from; Standard (""), Low Power
(""), Current Loop (".") and "". The Standard setting is the legacy
setting for use in wireless and wired scale networks. The maximum number of
scales that may be connected in a network is 32. The Low Power setting will
significantly improve the wireless battery life for all "non-host" scales. The Current
Loop setting is not used in the CW250. When scales are not part of a totalizing
network, battery life will be improved if "" is selected. Use the LOCAL/TOTAL
button or the ZERO button to cycle through the settings. When the desired protocol
setting is flashing, press the PRINT/ ACCUMULATE button.
12.The display will show ".". Press the PRINT/ACCUMULATE button. The display
will show the current Interface Baud Rate setting in flashing mode. Two baud rate
settings available; 9600 and 115200. Use the LOCAL/TOTAL button or the ZERO
button to toggle between the settings. When the desired baud rate setting is
flashing, press the PRINT/ ACCUMULATE button.