EasyManua.ls Logo

Intercomp CW250 - Mode Menu; Accessing the Mode Menu; Mode Menu Parameters Overview

Intercomp CW250
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CW250, Users
Rev M, April 2018
Page 18 of 31
Mode Menu
Mode Menu
To access the Mode Menu, press the PRINT/ACCUMULATE and ZERO buttons
simultaneously. The display will show the message ".". If the message is not
displayed, verify the Calibration Enable Jumper is in the "RUN" position (refer to the
"Calibration Enable Jumper" section).
When accessing the Mode Menu, it may be necessary to enter a number (up to a five
digit). This will be required when the current number is displayed with the far right digit
flashing. The flashing digit may be incremented by pressing the LOCAL/TOTAL button.
To move one digit to the left, press the ZERO key. When the number has been entered,
press the PRINT/ ACCUMULATE button. The settings are saved each time the
PRINT/ACCUMLATE button is pressed to advance the menu. The scale can then be
turned off.
Step
Function
Note
Default
.
Backlight
, ,


Set Point 1
0 to 199999


Set Point 2
0 to 199999

.
Firmware Version
View only
XXXXX
. 
Average Rate
1 to 120

.
Average Threshold
1 to 10000


Auto Off
000 = off, 1 to 240


Print Mode
0 = On-demand,
1 = Continuous
2 = Accumulating Total Axle,
3 = Accumulating Total Standard


Printer Baud Rate
1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200


Measurement Units
lb or kg
lb

Protocol
, , . or 

.
Interface Baud Rate
9600 or 115200


Radio Enable
Yes or no


Radio Channel
01 to 12

.
Radio Network ID
0 to 65534

.
Radio Encryption Key
0 to 65534

.
Restore Radio Defaults
0 or 3