17
 SPECIFICATIONS
5.1 Indoor unit
5.2 Outdoor unit
Technical information Unit Xtend-HB-AWHPSP05
Operating temperature range (heating) ºC -15 ºC to +25 ºC
Dimensions (H x W x D) mm 689 x 968 x 367
Weight (net) kg 43
Protection category IPX4
Technical information Unit
Xtend-HB-CUSP05
Operating temperature range ºC
+7 ºC to +40 ºC
Water in heating mode ºC
+7 ºC to +70 ºC
Maximum flow volume l/min
30
Dimensions (H x W x D) mm
557 x 163.5 x 275
Weight kg 10 (empty weight)
Protection category IPX1
5.3 Common specifications
Technical information Unit Value
Connection voltage/Frequency VAC/Hz 230/50
Maximum electrical power consumption kW 1.8
Maximum amperage A 7.8
Refrigerant type R32
Refrigerant GWP/CO equivalent 675/0.574
Refrigerant fill level weight kg 0.85