9.2.3 Checking the heating circuit
NOTES
Check the pressure (1.5 to 2 bar)
Check the inhibitor levels within the heating
system
Check the water-side connections to ensure
they are leak-tight.
Check if the system has been correctly
vented.
Check the system filter for debris and clean if
required.
Check all system valves, including the boiler
isolation valves, radiator lockshield & TRV's
etc. are open.
8. Check the system for any leaks, rectify where required.
9. Top-up the system pressure when required due to venting.
10. Close o both filling valves aer check the correct pressure has
been established.