Chapter 4: Web configuration
132 NS3552-8P-2S-V2 User Manual
The switch STP performs the following functions:
• Creates a single spanning tree from any combination of switching or bridging
elements.
• Creates multiple spanning trees from any combination of ports contained within a
single switch, in user specified groups.
• Automatically reconfigures the spanning tree to compensate for the failure, addition,
or removal of any element in the tree.
• Reconfigures the spanning tree without operator intervention.
Bridge protocol data units
For STP to arrive at a stable network topology, the following information is used:
• The unique switch identifier.
• The path cost to the root associated with each switch port.
• The port identifier
STP communicates between switches on the network using Bridge Protocol Data Units
(BPDUs). Each BPDU contains the following information:
• The unique identifier of the switch that the transmitting switch currently believes is
the root switch.
• The path cost to the root from the transmitting port.
• The port identifier of the transmitting port.
The switch sends BPDUs to communicate and construct the spanning-tree topology. All
switches connected to the LAN on which the packet is transmitted will receive the
BPDU. BPDUs are not directly forwarded by the switch, but the receiving switch uses
the information in the frame to calculate a BPDU and, if the topology changes, initiates
a BPDU transmission.
The communication between switches via BPDUs results in the following:
• One switch is elected as the root switch.
• The shortest distance to the root switch is calculated for each switch.
• A designated switch is selected. This is the switch closest to the root switch through
which packets will be forwarded to the root.
• A port for each switch is selected. This is the port providing the best path from the
switch to the root switch.
• Ports included in the STP are selected.
Creating a stable STP topology
The goal is to make the root port the fastest link. If all switches have STP enabled with
default settings, the switch with the lowest MAC address in the network becomes the
root switch. By increasing the priority (lowering the priority number) of the best switch,
STP can be forced to select the best switch as the root switch.

Table of Contents

Other manuals for Interlogix NS3552-8P-2S-V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NS3552-8P-2S-V2 and is the answer not in the manual?

Interlogix NS3552-8P-2S-V2 Specifications

General IconGeneral
BrandInterlogix
ModelNS3552-8P-2S-V2
CategorySwitch
LanguageEnglish

Related product manuals