EasyManua.ls Logo

Interlogix NS3552-8P-2S-V2 - Page 286

Interlogix NS3552-8P-2S-V2
511 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4: Web configuration
284 NS3552-8P-2S-V2 User Manual
This page includes the following fields:
General settings
Object Description
Enable Loop
Protection
Controls whether loop protections is enabled (as a whole).
Transmission Time The interval between each loop protection PDU sent on each port. Valid
values are 1 to 10 seconds.
Shutdown Time The period (in seconds) for which a port will be kept disabled in the event
that a loop is detected and the port action shuts down the port. Valid values
are 0 to 604800 seconds (seven days). A value of zero keeps a port
disabled until the next device restart.
Port configuration
Object Description
Port The switch port number.
Enable Controls loop protection enable/disable on this switch port.
Action Configures the action performed when a loop is detected on a port.
Selections include Shutdown Port, Shutdown Port and Log or Log Only.
Tx Mode Controls if the port is actively generating loop protection PDUs or if it is just
passively looking for looped PDU's.
Buttons
Click Save to save changes.
Click Reset to undo any changes made locally and revert to previously saved
values.
Loop protection status
The Loop Protection Status page shows the loop protection port status of the switch.

Table of Contents

Other manuals for Interlogix NS3552-8P-2S-V2

Related product manuals