104
Zone Number. Zone Name
• In Alarm – This zone has triggered a system alarm condition
• Is bypassed – This zone is isolated (disabled) and will not activate an alarm
• Chime is set – This zone is part of the chime group
• Is not secure – This zone is not closed
• Fire alarm – This zone has triggered a fire alarm
• Tamper – This zone has triggered a tamper alarm
• Trouble fault – This zone has an open circuit
• Loss of wireless supervision – This zone is a wireless device and has lost its communication
link with the control panel. For each sensor learned in the ZeroWire system, a heartbeat of 20
minutes is sent to ensure the sensor is monitored for presence.
Check battery, signal level, and
for interference.
• Low battery – This zone is a wireless device and needs its battery changed
UltraSync + app and Web Server Error Messages
Various error messages may appear on the ZeroWire Web Server and the UltraSync +
application.
Advanced/Settings Configuration menus
• "You must select a Menu before you can scroll" - An attempt was made to scroll up or down
from the top level menu.
• "Select a submenu from the list or select back to access the main menu" - An attempt was
made to scroll up or down from a submenu that has no additional levels.
• "Defaulting requires 2 levels" - a Shortcut was entered without two levels.
Read/write errors and results
• "Write Access Denied"
• "Nothing displayed can be Saved"
• "Program Success!"
Zones page
• "No Zones Configured For Your Access" - Displayed on Zones page when there are no zones
WiFi
• "Connection Was lost before a response was received" - Sent when no response received on a