EasyManuals Logo

Intermec PD41 User Manual

Intermec PD41
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Chapter 3 — Configuring the Printer
PD41 and PD42 Commercial Printer User’s Manual 45
Use the following table to understand the Web Shell settings.
Configuring Alerts
Use the Alerts page to view and change the printer alert settings.
To configure alerts
1 Click Printer > Alerts.
2 Change the alert settings:
Choose Enabled or Disabled from the Setting list.
Specify a Delay repeat in the text field.
Select seconds or occurrences in the Delay Unit list.
Enter a message in the Message text field.
3 Select the Notification method.
Understanding the Web Shell Settings
Setting Description
Testfeed [value] Calibrates the label stop sensor performs a
testfeed. Selecting this setting is equivalent to
issuing the TESTFEED command on the
printer.
Ribbon Sensor Detects is the printer has run out of ribbon
during printing.
Default Setup Returns the printer to factory default settings.
Passwords, alerts, and the selected application
are not changed.
Reboot Reboots the printer.
Print Test Label Prints the predefined test label you choose.
Command Language Sets the command language to Fingerprint,
Direct Protocol, IPL, ESim, ZSim, or DSim. You
need to reboot the printer for the change to take
effect.
Fingerprint Application Defines the application to run as the default on
startup. You need to reboot the printer for the
change to take effect.
Standard I/O Defines the port the printer listens to. You need
to reboot the printer for the change to take
effect.

Table of Contents

Other manuals for Intermec PD41

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec PD41 and is the answer not in the manual?

Intermec PD41 Specifications

General IconGeneral
Resolution203 dpi
Max Print Width4.1 inches
Max Print Speed6 inches per second
Print MethodDirect Thermal; Thermal Transfer
ConnectivityRS-232, USB, Parallel
Optional ConnectivityEthernet, Wireless
Media HandlingFan-fold
Media TypeRoll-fed or fanfold labels, tags, and tickets
Media Width1.0 to 4.65 inches
Memory8 MB Flash
Operating Temperature+5°C to +40°C (+41°F to +104°F)
Power Supply100-240 VAC, 50-60 Hz