Chapter 2 — Configuring the PW50
26 PW50 Workboard Printer User Guide
While the PW50 is in Extended Test mode, the Intermec
Ready-to-Work indicator and the Status LED indicate the
Extended Test mode option.
To restore the factory default settings
1 Press the Feed button to enter Factory Default mode.
The status LED is steady red.
2 Press the blue media cover release button to open the media cover.
3 Confirm you want to restore the factory default settings.
The LED is steady green, the factory default settings are restored,
and the PW50 reboots.
4 Close the media cover.
5 Perform a testfeed by holding down the Feed button until the
PW50 beeps.
Understanding Upgrade Mode
The PW50 is in Upgrade mode while it is upgrading firmware. While
the PW50 is in Upgrade mode, the Intermec Ready-to-Work indicator
and the green status LED blink. For more information about
upgrading firmware, see “Upgrading the Firmware” on page 22.
Extended Test Mode Options
Option Indicator Description
Test Prints Intermec Ready-to-Work
indicator is on
Allows you to print testprints one at a time.
Press the Feed button to print the next testprint.
Dump Mode Intermec Ready-to-Work
indicator is on and status
LED is steady red
Enters Dump mode. While the printer is in Dump
mode, it scans the communication ports. Any
characters received on the communication ports
are printed.
Press the Feed
button to enter Dump mode, and
press the Feed
button again to exit Dump mode.
Factory Default Status LED is steady green Restores the factory default settings.
Exit Intermec Ready-to-Work
indicator is on, status LED
is steady red, and status
LED is steady green
Exits Extended Test mode.
Press the Feed
button to exit Extended Test mode.