EasyManua.ls Logo

Invertek Drives Optidrive Series - Resetting Parameters to Factory Default Settings - Standard OLED Keypad (IP55 and IP66 Drives); Resetting Parameters to User Default Settings - Standard OLED Keypad (IP55 and IP66 Drives)

Invertek Drives Optidrive Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optidrive HVAC User Guide V2.00
28
www.invertekdrives.com
5
Managing the Keypad
5.8. Resetting Parameters to Factory Default Settings Standard OLED Keypad (IP55 and IP66 Drives)
Hold down the Up, Down, Start and
Stop keys for >2s
The display shows P-Def. Drive is
returned to factory settings. Press
the Stop key
Note: Parameters cannot be defaulted whilst P2-39=1 (parameter set locked).
5.9. Resetting Parameters to User Default Settings Standard OLED Keypad (IP55 and IP66 Drives)
The current parameter settings of the drive can be stored internally within the drive as the standard default settings. This does not affect the
procedure for returning the drive to factory default settings as described above.
P6-29 (Save user parameters as default) can be enabled (set to * to invoke a parameter save of the current parameter values as the standard
defaults for the drive. Parameter menu group 6 can only be accessed with advanced security level access (Default P1-14=20*.
Hold down the Up, Down, and Stop
keys for >2s
The display shows P-Def. Drive is
returned to User Standard settings.
Press the Stop key
Note: Parameters cannot be defaulted whilst P2-39=1 (parameter set locked).