IP Gear SmartCell 111L User Guide
4.10 Set Pulse Drop Signaling Method
4.10.1 Feature description
If the PABX trunk connected to the unit supports Pulse Drop signalling
method, you should use this command to set the unit to Pulse Drop signalling
mode
.
4.10.2 Feature Programming
Dial **1343**# [hear a confirmation tone] to enter programming mode.
Dial *7620*# [hear a confirmation tone].
4.11 Set Pulse Drop Width
4.11.1 Feature description
If Pulse Drop signalling method is used, the width of the pulse can be
controlled using this command. In general the pulse width
MUST be higher
than the parameter used by the PABX in order to be recognized by it (e.g. if the
PABX trunk is set to a pulse drop of 1 second then the pulse of the unit should
be set to 1.5 seconds). The pulse width is referred to by units of 100
milliseconds and can be anything between 100 ms and 9900 ms (99 units).
I.E.: to set the pulse width to 2 seconds (2000 ms), 20 should be programmed.
The default value for the pulse width is: 1.5 second (15 in the programming
mode).
4.11.2 Feature Programming
Dial **1343**# [hear a confirmation tone] to enter programming mode.
Dial *7630*# [hear a confirmation tone].
Dial 1 or 2 digits to set the desired width (100 ms to 9900 ms).
Example: to set the pulse drop width to 2 seconds dial *7630*# [hear a
confirmation tone] 20# [hear a confirmation tone].
Page 19