IP Gear SmartCell 111L User Guide
DB -113db)
dBm, BER:(0-7)
SWV Gets the software version
of the unit
SW VER: Q111xxxxxx
(Where xxxxxx states the
software version)
TRS Gets the Toll Restriction
table
TR IS OFF/ON,
xx,xx,xx,xx Stored (Where
xx defines the TR prefix
table)
VGR Gets the Rx Audio gain RECEIVE GAIN(+30 -
+51) intervals of 3db
VGT Gets the Tx Audio gain TRANSMIT GAIN(+6 - -
24) intervals of 2db
CEL Gets the current registered
cell information
Main Cell is: "Response
depends on the GSM
Network"
SIG Gets the signalling method Line Signal is Reverse
Polarity/Pulse Drop, XX
5.3 SET command table
Command Syntax Command Feature Applicable Response
SIG=P Set Signalling method to
Pulse Drop.
Line Signal is: Pulse Drop,
XX (Where XX is the
width of the pulse)
SIG=P,XX Set Signalling type to
Pulse Drop and the Length
of the pulse. Where XX
can be 1-99 (100
milliseconds to 9.9
seconds)
Line Signal is: Pulse Drop,
XX (Where XX is the
width of the pulse)
SIG=R Set Signalling type to
Reverse Polarity
Line Signal is: Reverse
Polarity
EMB=1 Erase the SMS inbox of
the SIM
Mailbox is Erased
RST=1 Reset the unit Restart Was Done.
Page 25