EasyManua.ls Logo

IP Gear SmartCell 111L - 4.16 Factory Default Values; 4.17 Call Progress tones

IP Gear SmartCell 111L
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IP Gear SmartCell 111L User Guide
DB -113db)
dBm, BER:(0-7)
SWV Gets the software version
of the unit
SW VER: Q111xxxxxx
(Where xxxxxx states the
software version)
TRS Gets the Toll Restriction
table
TR IS OFF/ON,
xx,xx,xx,xx Stored (Where
xx defines the TR prefix
table)
VGR Gets the Rx Audio gain RECEIVE GAIN(+30 -
+51) intervals of 3db
VGT Gets the Tx Audio gain TRANSMIT GAIN(+6 - -
24) intervals of 2db
CEL Gets the current registered
cell information
Main Cell is: "Response
depends on the GSM
Network"
SIG Gets the signalling method Line Signal is Reverse
Polarity/Pulse Drop, XX
5.3 SET command table
Command Syntax Command Feature Applicable Response
SIG=P Set Signalling method to
Pulse Drop.
Line Signal is: Pulse Drop,
XX (Where XX is the
width of the pulse)
SIG=P,XX Set Signalling type to
Pulse Drop and the Length
of the pulse. Where XX
can be 1-99 (100
milliseconds to 9.9
seconds)
Line Signal is: Pulse Drop,
XX (Where XX is the
width of the pulse)
SIG=R Set Signalling type to
Reverse Polarity
Line Signal is: Reverse
Polarity
EMB=1 Erase the SMS inbox of
the SIM
Mailbox is Erased
RST=1 Reset the unit Restart Was Done.
Page 25