Manual No. 0183B 10/29 IPC Series Service Manual
2.1.7 C2 Mode – Scale No. and Decimal point Setting
1) Scale No.[ X1 ] Table
X1 Specifications A/D Counts
1 3kg (2g/1g) Multi interval 30000 (20/10)
2 6kg (5g/2g) Multi interval 30000 (25/10)
3 15kg (10g/5g) Multi interval 30000 (20/10)
4 30kg (20g/10g) Multi interval 30000 (20/10)
5 3kg (1g) Single range 30000 (10)
6 6kg (2g) Single range 30000 (10)
7 15kg (5g) Single range 30000 (10)
8 30kg (10g) Single range 30000 (10)
9 6lb (0.005lb/0.002lb) / 3kg (2g/1g) Multi interval lb/kg 30000 (25/10) / 30000 (20/10)
A 15lb (0.01lb/0.005lb) / 6kg (5g/2g) Multi interval lb/kg 30000 (20/10) / 30000 (25/10)
B 30lb (0.02lb/0.01lb) / 15kg (10g/5g) Multi interval lb/kg 30000(20/10) / 30000 (20/10)
C 60lb (0.05lb/0.02lb) / 30kg (20g/10g) Multi interval lb/kg 30000(25/10) / 30000 (20/10)
D 100oz (0.1oz/0.05oz) Multi interval oz 20000 (20/10)
2) Decimal point indication [ X2 ] Table
X2 Display
1 "0"
2 "0.0"
3 "0.00"
4 "0.000"