Power Supply Function
throw load in 42V electrical system, where the upper limit is the protection volt-
age of throw load.
After turning on [On/Off] and triggering the waveform output, the instrument will
apply a test pulse to the DUT, as shown below:
t: Time (in ms)
U: Voltage (in V)
Supply Voltage Transient Drop
Simulate the affect from short circuit when fuse element of another circuit is
melt. Detect the function status of the DUT at transient drop of Voltage.
After turning on [On/Off] and triggering the waveform output, when the given
test pulse is applied at all input terminals of the DUT, the rise and fall time be-
tween U
low
and 16V level shall not be longer than 100ms.
t: Time (in ms)
U: Voltage (in V)