EasyManua.ls Logo

ITech IT6723H - Chapter3 Status Commands; Status:questionable[:Event]; Status:questionable:condition; Status:questionable:enable <Enabled Value

ITech IT6723H
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Status commands
Copyright © Itech Electronic Co., Ltd. 17
Chapter3 Status commands
STATus:QUEStionable[:EVENt]?
This order can read the parameter from quest event register. the power supply
will return a decimal number which is corresponding to the binary weighted sum
of each bit of the register, these bits have been latched. After executing, quest
event register is reset.
Quest syntax
STATus:QUEStionable[:EVENt]?
Parameter
None
Return parameter
<NR1>
Reference order
STATus:QUEStionable:ENABle
STATus:QUEStionable:CONDition?
This order can be used to read the value of query condition register and to get
the status of the power, if it is CC or CV,. The power supply will return a decimal
number corresponding to the binary-weighted sum of each bit of the
register. These bits are not latched. If 0 is returned, then the output
status of the power is OFF or uncertain. If 1 is returned, then the status is
CC mode, if 2 is returned, then the status is CV. If 3 is returned, then
there is error occurred.
Quest syntax
STATus:QUEStionable:CONDition?
Parameter
None
Return parameter
<NR1>
STATus:QUEStionable:ENABle <enabled value>
This order can set the parameter of quest event enable register. The power
supply will return a decimal number which is the binary-weighted sum of the
enable register.